Self-contained low pressure cables

Lighting string (L) Phase conductor (F) The number and  area of the conductors
Insulation
Thickness
mm
No.of
Stands Dia
N*MM
Insulation
Thickness
mm
No.of
Stands Dia
N*mm
No.of
Conductors
mm2
No.of Conductors
Cross-Section
mm2
1.4 7*2.14 1.8 19*2.52 3*95 3*95/25/70
1.2 7*1.7 1.8 19*2.14 3*70 3*70/16/70
1.2 7*1.7 1.6 7*2.93 3*50 3*50/16/50
1.2 7*1.7 1.6 7*2.52 3*35 3*35/16/50
1.2 7*1.7 1.6 7*2.52 1*35 3*35/16/50
Weight  N&Messenger
The number and area of the conductors
Weight appr.
Kg/km
Aluminium
Weight appr.
Kg/km
Insulation
Thickness
mm
No.of
Conductors
mm2
No.of Conductors
Cross-Section
mm2
1360 196 1.6 7*3.60 3*95/25/70
1060 196 1.6 7*3.60 3*70/16/70
815 148 1.6 7*3.15 3*50/16/50
690 148 1.6 7*3.15 3*35/16/50
425 148 1.6 7*3.15 3*35/16/50
Lighting string (L) Phase conductor(F) The number and  area of the conductors
Insulation
Thickness
mm
No.of
Stands Dia
N*MM
Insulation
Thickness
mm
No.of
Stands Dia
N*mm
No.of
Conductors
mm2
No.of Conductors
Cross-Section
mm2
1.2 7*1.67 1.45 7*2.52 3*35 3*35/16+25+25
1.2 7*1.67 1.65 7*2.93 3*50 3*50/16+35+25
1.2 7*1.62 1.65 19*2.14 3*70 3*70/16+50+25
1.4 7*2.14 1.8 19*2.52 3*95 3*95/25+70+25
Weight The keeper(Messenger) Null string(N) The number and area of the conductors
Weight appr.
Kg/km
Aluminium
Weight appr.
Kg/km
Insulation
Thickness
mm
No.of
Stands Dia
N*MM
Insulation
Thickness
mm
No.of
Conductors
mm2
No.of Conductors
Cross-Section
mm2
734 383 1.1 7*1.93 1.4 7*2.14 3*35/16+25+25
930 523 1.1 7*1.93 1.45 7*2.52 3*50/16+35+25
1193 736 1.1 7*1.93 1.65 7*2.93 3*70/16+50+25
1579 1051 1.1 7*1.93 1.65 19*2.14 3*95/25+70+25

Weight
the keeper
(
Messenger)
Lighting string (L) Null string (N) Phase conductor (F)

No.Of Conductors
Corss-Section
mm2

Weight appr.
Kg/km

Steel
Weight appr
Kg/km

Aluminium
Weight appr.
Kg/km

Insulation
Thickness
mm 

No.of
Stands Dia
N*mm2

Insulation
Thickness
mm 

No.of
Stands Dia
N*mm2

Insulation
Thickness
mm 

No.of
Stands Dia
N*mm2

Insulation
Thickness
mm

No.of
Stands Dia
N*mm2

No.of
Conductors
mm2

597 108 313.158 1.2 7*1.57 1.2 7*1.67 1.4 7*2.14 1.4 7*2.14 3*25 3*25+25+16+16
842 162 444.817 1.2 7*1.93 1.4 7*2.14 1.6 7*2.52 1.6 7*2.52 3*35 3*35+35+25+25
1005 162 577.425 1.2 7*1.93 1.4 7*2.14 1.6 7*2.93 1.6 7*2.93 3*50 3*50+50+25+25
1303 162 805.633 1.2 7*1.93 1.4 7*2.14 1.8 19*2.14 1.8 19*2.14 3*70 3*70+70+25+25
1618 162 1090.881 1.2 7*1.93 1.4 7*2.14 1.8 19*2.52 1.8 19*2.52 3*95 3*95+95+25+25
1915 162 1358.033 1.2 7*1.93 1.4 7*2.14 1.8 19*2.83 1.8 19*2.83 3*120 3*120+120+25+25
XLpe Insulated Three & Four Core Power Cable

Weight
The keeper
(
Messenger)
Lighting string (L) Null string (N) Phase conductor (F)

No.Of Conductors
Corss-Section
mm2

Weight appr.
Kg/km

Steel
Weight appr
Kg/km

Aluminium
Weight appr.
Kg/km

Insulation
Thickness
mm 

No.of
Stands Dia
N*mm2

Insulation
Thickness
mm 

No.of
Stands Dia
N*mm2

Insulation
Thickness
mm 

No.of
Stands Dia
N*mm2

Insulation
Thickness
mm

No.of
Stands Dia
N*mm2

No.of
Conductors
mm2

399 108 177.268 1.2 7*1.57 1.2 7*1.67 1.4 7*2.14 1.4 7*2.14 1*25 1*25+25+16+16
532 162 229.814 1.2 7*1.93 1.2 7*1.67 1.6 7*2.52 1.6 7*2.52 1*35 1*35+35+16+25
261 108 82.756 1.2 7*1.57 …… …… 1.2 7*1.67 1.2 7*1.67 1*16 1*16+16+16
333 108 135.9 1.2 7*1.57 …….. ……… 1.4 7*2.14 1.4 7*2.14 1*25 1*25+25+16